Add your idea or search for answers in existing topics. The most popular ideas will be implemented faster!

We have moved our support service to a new technical support system. Since 17.01.2022, we have disabled the ability to create appeals through the userecho personal account. Now all requests are processed via mail to support@iridi.com .

Thank you for your understanding and have a nice day.

0
Under review

Problem with feedback from multizone tcp controller

oggi katic 8 jaar geleden in Products / AV & Custom Systems bijgewerkt door Jackie Roos 8 jaar geleden 6

I have a problem to get a feedbeck from my multiroom controller.

i can control system when sending commands like this one:

'#|X001|web|SVD01|0|U|',13,10


But i can't get any feedback from controller and the only commandes i have from manufaktur is:


Example Get routing info for zone 1 Command


#|X001|web| GV01|0|U|return

Answer #|web|X001| V01|20|U|return


I have tried to read feedback into a value or text field but without succes.


i hope somebody can halp.. thx

0
Voltooid

Камеры панелей управления в Iridium

diimn 8 jaar geleden in Products / Other drivers bijgewerkt door Ekaterina (head of support) 8 jaar geleden 1

Столкнулись с задачей реализации видеоинтеркома. Имеется частный дом, несколько этажей, пользователь хочет помимо аудио-интеркома, еще картинку. Так же это может быть использовано, например, для удаленного просмотра происходящего в области видимости камеры, особенно если панель установлена на постоянное место, это позволит частично заменить бросающуюся в глаза ip-камеру. Видеоняню можно записать сюда же.

0
Beantwoord

Number of KNX group addresses with i2control V2.2

Patrick PETIT 9 jaar geleden in Products / KNX bijgewerkt door Theo Derks - NL (distributor) 9 jaar geleden 6
Hello,
Are there a limitation on the number of KNX group addresses with i2control V2.2. I use the Weinzierl BAOS 772 interface that can handle 1000 address groups
Patrick
0
Beantwoord

Dry HDL Status in BackGround

Paolo Scarpetta 9 jaar geleden in Products / HDL-BUS Pro bijgewerkt door Ekaterina (head of support) 9 jaar geleden 4

I want to make a simple warning system of technical alarms. For this I use a dry contact module of HDL.

The system works correctly, when I'm inside it, but when I´m running in the background is not working. What can be wrong?

Attach the project to be better understood.


Note: To make the system work I had to use the "Security Dry Contact Read Status" option and also had to make ask the state of this variable at some time period, otherwise not give me the information about the state of the dry contact.

Alarm Dry.irpz

0
Planned

​In the AMX driver does not work the command ^RMF

Martin Petrašovský 9 jaar geleden in Products / AMX bijgewerkt door Ekaterina (head of support) 9 jaar geleden 5
In the AMX driver does not work the command ^RMF this is a known bug?
0
Beantwoord

Adjusting temperature in Domintell

Patrick V 9 jaar geleden in Products / Other drivers bijgewerkt door Ekaterina (head of support) 9 jaar geleden 1
Hello, can anyone help me out on this?
Reading the temperature is no problem but I can not find how to adjust the temperature in a specific room. Everything is controled by Domintell.
0
Beantwoord

Project coolmaster 1000D

Vuong Xuan Phuc 9 jaar geleden in Products / Other drivers bijgewerkt door iRidiumNikita 9 jaar geleden 2
I have a project Coolmaster 1000D by i2_fixed_stat. I try to use and it can be get feedback state of device. But i can't see script because it have a password. Can you send the pass word off script or tell me how to get the feedback from coolmaster 1000D. Thanks
0
Beantwoord

Modbus protocol in Background execution mode

Sorbodoekje 9 jaar geleden in Products / Modbus bijgewerkt door Oksana (expert) 9 jaar geleden 1
I made an app, which communicates with a PLC. I enabled backgound mode. But when I close i2 Control, the communication stops after 2 minutes. That while I enabled the Don't Sleep in the settings! I tested this on iOS8 and 9, but same behavior...
Am I doing something wrong?
Antwoord
Oksana (expert) 9 jaar geleden
Hello!

At the moment notifications for the background mode (minimized or closed application) are not supported. http://wiki2.iridiummobile.net/Working_with_Equipment#Notifications_about_System_Events

Function "Don't sleep" doesn't let your device sleep if the app is active (it isn't minimized or closed)

Sincerely yours,
Oksana Storozheva
iRidium mobile Team


0
Beantwoord

TCP TO UDP GAte

Punith 9 jaar geleden in Products / HDL-BUS Pro bijgewerkt door Olga (expert) 9 jaar geleden 1
Regarding TCP TO UDP , i put dyndns host name into the project and i put port of 10005 in iridium GUI editor project, I have put on running mode in iridium gate ,,,SO It is working via internet only and it doesnot work locally: what i should do it
Antwoord
Olga (expert) 9 jaar geleden
Dear Punit,

iRidium has a special command which changes the external address to the internal one:
http://wiki2.iridiummobile.net/Basic_Operation_of_iRidium_with_Modbus_Controllers#Switching_Between_the_Local_and_Internet_Connection
You need to use it for switching between the local network and the Internet.
If the connection doesn't work when working in the local network, it means that the router blocks the connection. It is standard for many routers. You can change the router or use the ready tool for switching networks.

Sincerely yours,

Olga Ermakova
iRidium mobile Team
0
Beantwoord

Recive Feedback from lighting in My Home System - Bticino

Vuong Xuan Phuc 9 jaar geleden in Products / Other drivers bijgewerkt 9 jaar geleden 2

Hello everybody.

I use iRidium to control MyHome system.
I have done project with iRidium when i control lighting with A=1-9 PL=1-9 it control and feedback success. But with A=1-9 PL=10-15 it can control but it do not feedback ?
I want to ask how to get feedback with PL>=10; thanks